Model: Fluke 355 True RMS 2000 A Clamp Meter

Fluke 355 True RMS 2000 A Clamp Meter accurately measures frequency up to 1 kHz for optimum troubleshooting.

Versatile and rugged tools for applications with high currents.

Confidently take reliable readings with verity RMS, Fluke 355 digital clamp meter the tool of selection for prime current clamp-on amp meter measure up to 2000 A. The extra-wide jaw simply clamps around giant conductors, generally found in high-current applications. the additional rugged style and CAT IV 600 V, CAT III a thousand V ratings add an additional part of user protection once taking high-powered measurements.

Accurate peak measurements may be taken victimization the in-rush current mode, ideal for motors and inductive masses. The 355 additionally measures voltage and resistance, creating this a perfect clamp meter for utilities, electrical contractors, and industrial service engineers.

We provide the top class clamp meter in Bangladesh. Fluke Bangladesh owned & operated by us. As a Fluke agent company, we always supply the best clamp meter for our customers.

Specifications: Fluke 355 True RMS 2000 A Clamp Meter

Electrical Specifications
Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC rms
Resolution 10 mA / 100 mA / 1 A
Accuracy A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC rms
Crest Factor1 2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC rms
Resolution 10 mA / 100 mA / 1 A
Accuracy 10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Voltage measurement DC and AC 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)
Range 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC
Resolution 1 mV / 10 mV / 100 mV / 1 V
Accuracy 1% rdg + 10 digits
1% rdg + 5 digits
Trigger level for Hz filter OFF 0.25 V / 6 V
Trigger level for Hz filter ON 0.25 V / 6 V
Voltage measurement AC 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)
Range 4 V / 40 V / 400 V / 600 V ac rms
Resolution 1 mV / 10 mV / 100 mV / 1 V
Accuracy 3% rdg + 10 digits
3% rdg + 5 digits
Trigger level for Hz filter OFF 0.050 V / 0.25 V / 6 V
Trigger level for Hz filter ON 0.050 V / 0.25 V / 6 V
Ohms measurement Range 4 kΩ / 40 kΩ / 400 kΩ
Resolution 0.1 Ω / 1 Ω / 10 Ω / 100 Ω
Accuracy 1.5% + 5 digits
Continuity beeper On at ≤ 30 Ω
Off at ≥ 100 Ω
Frequency measurement Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2% + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5% + 5 counts
Trigger level Refer to current and voltage tables
1. Add 2% to error spec for CF > 2
General Specifications
Batteries Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off) 100 hours
Test leads Rated to 1000 V
Weight .814 kg (1.8 lb)
Jaw size 58 mm (2.28 in)
Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in)
Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental Specifications
Operating temperature 32°F to +122°F (0°C to +50°C)
Storage temperature -4°F to 140°F (-20°C to +60°C)
Operating humidity 0 to 95% (non-condensing)
Operating altitude 2000 m
Storage altitude 10,000 m
IP rating 42 (indoor use only)
Drop test requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325
Temperature coefficients Current 0.1% of reading per °C outside 22°C to 24°C
Voltage 0.1% of reading per °C outside 22°C to 24°C

Key features: Fluke 355 True RMS 2000 A Clamp Meter

  • Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
  • Resistance to 400K ohms coupled with a continuity beeper provides the convenience of a multimeter in a clamp meter.
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

Trending Items

Fluke 115 True-RMS Digital Multimeter

Fluke 115 True-RMS Digital Multimeter

Good
Fluke Ti400 Thermal scanning Camera

Fluke Ti400 Thermal scanning Camera

Good
Fluke 376 True RMS AC/DC Clamp Meter

Fluke 376 True RMS AC/DC Clamp Meter

Good
Fluke TiS20+ MAX Thermal Scanner

Fluke TiS20+ MAX Thermal Scanner

Good

You May Like Also

Amprobe ACDC-3400 IND AC-DC CAT IV TRMS Clamp Meter

Amprobe ACDC-3400 IND AC-DC CAT IV TRMS Clamp Meter

Good
Amprobe ACD-14-PRO Dual Display 600 A TRMS Clamp Meter

Amprobe ACD-14-PRO Dual Display 600 A TRMS Clamp Meter

Good
Fluke 375 True RMS AC/DC Clamp Meter

Fluke 375 True RMS AC/DC Clamp Meter

Good
Fluke 373 True-RMS AC Clamp Meter

Fluke 373 True-RMS AC Clamp Meter

Good